Ditch Witch JT2020 User Manual

Page 172

Advertising
background image

JT2020 Mach 1 Operator’s

Manual

Service - 171

Startup/10 Hour

CMW

Check Pipe Lube Applicator

Check pipe lube applicator before startup and every 10 hours of operation. Replace if damaged or badly
worn.

Check Pipe Auto Lubricator Spray Nozzle

Check pipe auto lubricator spray nozzle before startup and every 10 hours of operation. Ensure that nozzle
is free of obstructions and operates properly. Clean as needed.

To clean:

1.

Rotate handle to the upward, or cleanout, position (A).

2.

Operate pump until obstruction is flushed.

3.

Rotate handle to the downward, or spray, position (B).

4.

Clean nozzle guard. If necessary, pull handle/nozzle insert out of housing to clean with fine wire or
solvent.

NOTICE: Ditch Witch tool joint compound is specially formulated to work with Ditch Witch pipe
lubrication system. Use of other tool joint compounds will clog system. See “Recommended Lubricants/
Service Key” on page 163 for more information.

Advertising