Prime drilling fluid pump – Ditch Witch JT2020 User Manual

Page 95

Advertising
background image

Conduct a Bore - 94

JT2020 Mach 1 Operator’s Manual

Prime Drilling Fluid Pump

CMW

Prime Drilling Fluid Pump

Prime drilling fluid pump each time tank is changed. To prime the pump:

1.

Fill drilling fluid hose and connect hose to unit.

2.

Operate mixing/transfer pump at full speed for 1 - 3 minutes to discharge air from system.

3.

Return mixing/transfer pump to normal operating speed and continue the bore.

4.

If drilling fluid pressure surges are observed, repeat step 2.

Incorrect procedures could result in death, injury, or property damage.

Learn to use equipment correctly.

NOTICE: Failure to prime the drilling fluid pump will cause flow fluctuations, which will
make it difficult to control the washwand.

Pressurized fluid or air could pierce skin and cause injury

or death. Stay away.