Working with OTDR Files

Post Processing Software

161

Managing Bidirectional OTDR Files (FR2-FC Mode)

Creating Bidirectional Measurement Files

You can combine unidirectional measurements into a bidirectional
measurement file. It is possible to use both single-wavelength and
multiwavelength measurements. FastReporter 2 matches the wavelengths.

The A->B and B->A measurement files must respect the following criteria:

To create bidirectional files in FastReporter 2, you must first match A->B
files with B->A files. For information on file matching, see Matching Files
on page 48. Cha
nges made to event matching tolerances will affect
bidirectional event table results.

Item

To be valid

Pulse width

Must be identical for both measurement files.

Fiber types

Use only measurements acquired using

singlemode fibers.

Wavelengths

Must be identical for both measurements.

Measurement file

Both must be unidirectional files.

Advertising