Generating, Previewing and Printing Reports

294

FastReporter 2

Using Excel Report Templates

Using the Configuration Sheet

The configuration sheet contains three parts.

Flags

Sheet Details

Filter Details

Flags are used to specify to Excel how to handle specific behavior as well
as data display. By default, you have access to two different flag settings,
Apply Thresholds and Cell Merging. These flag settings are visible in the
Configuration sheet. The table below contains details for each flag setting.

Setting

Purpose

Note

Apply Thresholds Apply pass/fail thresholds

from FastReporter 2, that is

change font and

background color used in

the application.

True = will use threshold

from FastReporter 2
False = no threshold

applied. It can use

conditional formatting from

Excel.

Cell Merging

Merges cells with matched

records. For example, if the

FiberID is the same for 3

measurements, they are

merged into a single cell

To improve the

performance, this option is

always to "False" in all the

report templates, except in

the FiberCharacteration

template. This should be set

to "True" when extra

processing is done with

Excel's Pivot table.