Overview of redundancy, Procedure, 1 overview of redundancy procedure – Pilz PSSnet SHL 8T MRP User Manual

Page 10

Advertising
background image

Introduction

10

1.1 Overview of

Redundancy

Procedure

PSSnet SHL - Redundancy Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

1.1 Overview of

Redundancy Procedure

Redundancy
procedure

Network topology

Switching time

RSTP

Random structure

typically < 1 s (STP < 30 s), up to < 30 s - depends
heavily on the number of devices

Note: Up to 79 devices possible, depending on topology and configuration. If
the default values are being used, up to 39 devices are possible, depending on
the topology

(see page

53)

.

HIPER-Ring

Ring

typically 80 ms, up to < 500 ms - practically indepen-
dently of the number of devices

MRP-Ring

Ring

typically 80 ms, up to < 500 ms - practically indepen-
dently of the number of devices

Note: In combination with RSTP in MRP compatibility mode, up to 39 devices
are possible, depending on the configuration. If the default values for RSTP are
being used, up to 19 devices are possible

(see page

53)

.

Redundant
coupling

Coupling of network
segment/rings via a
main line and a
redundant line

typically 150 ms, up to < 500ms

Table 1: Comparison of the redundancy procedures

Advertising
This manual is related to the following products: