Pilz PSSnet SHL 8T MRP User Manual

Page 40

Advertising
background image

Ring/Network coupling

40

3.2 Preparing a Ring/Network cou-

pling

PSSnet SHL - Redundancy Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

Note: If you are operating the Ring Manager and two-Switch coupling func-
tions at the same time, there is the risk of creating a loop.

Note: The following settings are required for the coupling ports (you
select the Basic Settings:Port Configuration dialog):

– Port: on
– Automatic configuration (autonegotiation):

on for twisted-pair connections

– Manual configuration: 100 Mbit/s FDX

for glass fiber connections

Note: If VLANS are configured, note the VLAN configuration of the
coupling and partner coupling ports.
In the Network/Ring Coupling configuration, select for the coupling and
partner coupling ports
– VLAN ID 1 and “Ingress Filtering” disabled in the port table and
– VLAN membership U in the static VLAN table.

…

Select two-Switch redundant coupling

(see fig.

18)

.

Figure 17: Two-Switch coupling

1: Coupling port
2: Partner coupling port

The following settings apply to the Switch displayed in blue in the
selected graphic.
…

Select the coupling port

(see fig.

16)

,

(see table

7)

.

With “Coupling port” you specify at which port you are connecting
the network segments.

…

If the STANDBY DIP switch is ON, connect the main line to the
coupling port.

I O

STAND-BY

2

1

Advertising