Ring/Network coupling

48

3.2 Preparing a Ring/Network cou-

pling

PSSnet SHL - Redundancy Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

Note: Configure the coupling port and the redundancy ring ports on different
ports.

…

Select two-Switch redundant coupling
with control line

(see fig.

24)

.

Figure 24: Two-Switch coupling with control line

1: Coupling port
2: Partner coupling port
3: Control line

The following settings apply to the Switch displayed in blue in the
selected graphic.
…

Select the coupling port

(see fig.

23)

,

(see table

9)

.

With “Coupling port” you specify at which port you are connecting
the network segments.

…

If the STANDBY DIP switch is ON, connect the main line to the
coupling port.

…

Select the control port

(see fig.

23)

,

(see table

9)

.

With “Control port” you specify at which port you are connecting the
control line.

…

Activate the function in the “Operation” frame

(see fig.

16)

.

…

You now connect the redundant line and the control line.

The displays in the “Select port” frame mean

(see fig.

23)

:

– “Port mode”: The port is either active or in stand-by mode.
– “Port state”: The port is either connected or not connected.
– “IP Address”: The IP address of the partner, if the partner is already

operating in the network.