Ring/Network coupling

50

3.2 Preparing a Ring/Network cou-

pling

PSSnet SHL - Redundancy Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

Figure 25: Selecting the redundancy mode

With the “Redundant Ring/Network Coupling” setting, either the main
line or the redundant line is active. Both lines are never active simulta-
neously.
With the “Extended Redundancy” setting, the main line and the redun-
dant line are simultaneously active if the connection line between the
devices in the connected network fails

(see fig.

12)

.

During the reconfiguration period, there may be package duplications.
Therefore, only select this setting if your application detects package
duplications.

Figure 26: Extended redundancy

Coupling mode
The coupling mode indicates the type of the connected network.
…

In the “Coupling Mode” frame, select

(see fig.

27)

– “Ring Coupling” or
– “Network Coupling”