background image

Ring Redundancy

PSSnet SHL - Redundancy Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

2.1 Example of HIPER-Ring

15

2.1.1 Setting up and configuring the HIPER-Ring

…

Set up the network to meet your requirements.

…

You configure all 6 ports so that the transmission speed and the duplex
settings of the lines correspond to the following table:

Bit rate

100 Mbit/s

1000 Mbit/s

Autonegotiation
(automatic configuration)

off

on

Port

on

on

Duplex

Full

Table 2: Port settings for ring ports

…

Select the Redundancy:Ring Redundancy dialog.

…

Under “Version”, select HIPER-Ring.

…

Define the desired ring ports 1 and 2 by making the corresponding
entries in the module and port fields. If it is not possible to enter a
module, then there is only one module in the device that is taken
over as a default.