9 Project window
9.1.12
Analog I/O
Analog-Inputs – Function [
ANCNFG
]
The ANCNFG command configure the analog inputs.
Offset [
ANOFF1
-
ANOFF2
]
Adjust the axis to standstill while the setpoint SW=0V.
Filter [
AVZ1
-
AVZ2
]
You can enter a filter time constant here, for setpoint 1 (clock rate 8 kHz)
(1st order filter).
Velocity Scale [
VSCALE1
-
VSCALE2
]
Scaling of the speed setpoint value.
Current Scale [
ISCALE1
-
ISCALE2
]
Scaling of the torque setpoint value.
Velocity Deadband [
ANDB
]
Suppresses small input signals.
Analog Output 1+2 [
ANOUT1
–
ANOUT2
] – PMCtendo DD4 only
Configuration of the analog outputs.