Handling the board, Handling the board –4 – Altera SDI HSMC User Manual

Page 8

Advertising
background image

1–4

Chapter 1: Overview

Handling the Board

SDI HSMC Reference Manual

© July 2009 Altera Corporation

Handling the Board

When handling the board, it is important to observe the following precaution:

c

Static Discharge Precaution: Without proper anti-static handling, the board can be
damaged. Therefore, use anti-static handling precautions when touching the board.

The SDI HSMC must be stored between –40° C and 100° C. The recommended
operating temperature is between 0° C and 55° C.

Figure 1–2. SDI HSMC Block Diagram

TX 1 DATA

SDI TX 1

EQ 1

SDI RX 1

Video Sync

Separator

Video In

148.5 MHz

HSYNC

VSYNC

Buffer

PLL

PLL Ref / Rec CLK

TX 2 DATA

SDI TX 2

RX 1 DATA

EXT CLK

IN

SDI CLK
OUT (P)

DRV 1

DRV 2

EQ 2

SDI RX 2

RX 2 DATA

AES RX 1

AES TX DATA

AES TX 1

AES RX DATA

AES Passive

Circuit

AES Passive

Circuit

AES RX 2

AES TX DATA

AES TX 2

AES RX DATA

AES Passive

Circuit

AES Passive

Circuit

FRAME

SDI CLK
OUT (N)

TX

RX

TX

RX

AES Loop

Filter

VCXO

xtal

AES CLK
SMA

16.384 MHz

AES CLK

down

up