Handling the board, Handling the board –4 – Altera SDI HSMC User Manual
Page 8
1–4
Chapter 1: Overview
Handling the Board
© July 2009 Altera Corporation
Handling the Board
When handling the board, it is important to observe the following precaution:
c
Static Discharge Precaution: Without proper anti-static handling, the board can be
damaged. Therefore, use anti-static handling precautions when touching the board.
The SDI HSMC must be stored between –40° C and 100° C. The recommended
operating temperature is between 0° C and 55° C.
Figure 1–2. SDI HSMC Block Diagram
TX 1 DATA
SDI TX 1
EQ 1
SDI RX 1
Video Sync
Separator
Video In
148.5 MHz
HSYNC
VSYNC
Buffer
PLL
PLL Ref / Rec CLK
TX 2 DATA
SDI TX 2
RX 1 DATA
EXT CLK
IN
SDI CLK
OUT (P)
DRV 1
DRV 2
EQ 2
SDI RX 2
RX 2 DATA
AES RX 1
AES TX DATA
AES TX 1
AES RX DATA
AES Passive
Circuit
AES Passive
Circuit
AES RX 2
AES TX DATA
AES TX 2
AES RX DATA
AES Passive
Circuit
AES Passive
Circuit
FRAME
SDI CLK
OUT (N)
TX
RX
TX
RX
AES Loop
Filter
VCXO
xtal
AES CLK
SMA
16.384 MHz
AES CLK
down
up