JA - Jog Acceleration

Compatibility: All drives
Affects:

CJ, WI (jogging) commands

See also:

CJ, CS, JD, JE, JL, JS, SJ

Sets or requests the accel/decel rate for Jog moves in rev/sec/sec. Sending JA with no parameter causes drive to
respond with present jog accel/decel rate. Setting JA overwrites the both the last JA and JL values. This means
that to have different jog accel and jog decel values, you should first send JA to set the jog accel and then send JL
to set the jog decel. The JA value cannot be changed while jogging.

Command Details:

Structure

JA{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

None

Parameter Details:

Parameter #1

Jog acceleration value

- units

rev/sec/sec (rps/s)

- range

0.167 to 5461.167 (resolution is 0.167 rps/s)

Examples:

Command

Drive sends

Notes

JA100

-

Set jog acceleration to 100 rev/sec/sec

JA JA=100