Applied Motion RS-232 User Manual

Page 297

Advertising
background image

297

920-0002 Rev. I

2/2013

Host Command Reference

Command

Description

opcode (hex)

Reg code

Parameter 1

Parameter 2

Parameter 3

Parameter 4

Range ST5 /

ST10 / ST

AC5

Units

HW

Hand wheel

AB 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

JA

VM_ACCEL,

1B 0

jog accel rate 1..32000

10 rpm/sec

JD

JOG_DISABLE

A3 0

JE

JOG_ENABLE

A2 0

direction

1=cw enable, 2=ccw

enable, 3=both

JL

VM_DECEL,

1C 0

jog decel rate 1..32000

10 rpm/sec

JS

VM_VELOCITY,

1A 0

jog speed

0..32000

.25 rpm

MD

MOTOR_DISABLE

9E 0

ME

MOTOR_ENABLE

9F 0

MT

Multi Tasking

A9 0

0

0 or 1 0 or 1

1=on, 0=off

SH

SEEK_HOME, ionum+cond 6E 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

SM

STOP_MOVING

B5 0

decel code

D (DE rate) or M (AM

rate)

‘D’ or ‘M’

SP

SET_ABS_POSITION

A5 0

32 bit abs position

+/-2,147,483,647

steps

VC

CHANGE_VELOCITY,

4A 0

speed

1..32000

.25 rpm

VE

P_TO_P_VELOCITY,

1D 0

speed

1..32000

.25 rpm

WI

Wait for Input

70 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

WM WAIT_ON_MOVE

BC 0

WP

WAIT_ON_POSITION

D0 0

Configuration Commands
--

RESTORE_DEFAULTS

A6

AD

Analog Deadband

D2 0

dead band

0..255

millivolts

AS

Analog Scaling

D1 0

scale code

0..7

0 = single-ended +/- 10 volts

1 = single-ended 0 - 10 volts

2 = single-ended +/- 5 volts

3 = single-ended 0 - 5 volts

4 = differential +/- 10 volts

5 = differential 0 - 10 volts

6 = differential +/- 5 volts

7 = differential 0 - 5 volts

BD

BRAKE RELEASE DELAY

40 0

brake release

delay

1..32000

msec

BE

BRAKE ENGAGE DELAY

41 0

brake engage

delay

1..32000

msec

CA

ACCEL_CURRENT,

61 0

accel current

not supported

10 rpm/sec

Advertising