Ap - analog position gain, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 31: Examples

Advertising
background image

31

920-0002 Rev. I

2/2013

Host Command Reference

AP - Analog Position Gain

Compatibility: All drives
Affects:

CM22 (Analog Positioning Command Mode)

See also:

AD, AF, AZ, CM, SF commands

Sets or requests the analog Input gain that relates to motor position when the drive is in analog position command
mode (see CM command, parameter value 22). Gain value sets the commanded position when the analog input
is at the configured full scale value. Quick Tuner (BLu, SV), STAC6 Configurator (STAC6), or ST Configurator (ST,
STM) can be used to configure the analog inputs for the desired input type, scaling and offsetting.

Command Details:

Structure

AP{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

“X” (040)

Parameter Details:

Parameter #1

Analog position gain value

- units

encoder counts

- range

0 - 32767

Examples:

Command

Drive sends

Notes

AP8000

-

Position range over full scale of analog input is 8000 steps

AP AP=8000

Advertising
This manual is related to the following products: