Vi - velocity integrator constant, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 214: Examples

Advertising
background image

214

920-0002 Rev. I
2/2013

Host Command Reference

VI - Velocity Integrator Constant

Compatibility: Servo drives only
Affects:

Jog commands

See also:

VP & JM commands

Sets or requests the velocity-mode (“JM2”) servo control integrator gain term. Gain value is relative: 0 = no gain,
32767 = full gain. VI minimizes steady state velocity errors.

Command Details:

Structure

VI{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

None

Parameter Details:

Parameter #1

Velocity integrator gain value

- units

integer (no specific units)

- range

0 - 32767 (0% - 100%)

Examples:

Command

Drive sends

Notes

VI5000

-

Set velocity integrator gain to 5000

VI VI=5000

Advertising