Host Command Reference

*Current setting in stepper drives depends on the selected motor. Use Configurator software to select a motor
and set the maximum current setting.

Examples:

BLu, SV, SVAC3

Command

Drive sends

Notes

CC4.50

-

Set continuous current to 4.5 amps rms

CC CC=4.5

STAC6

Command

Drive sends

Notes

CC4.50

-

Set running current to 4.5 amps

CI2

-

Set idle current to 2.0 amps

CC1.8

-

Set idle current to 1.8 amps

CC CC=1.8
CI

CI=1.8

CI automatically set to 1.8 amps along with CC1.8 command

ST-Q/Si, ST-S, STM, STAC5

Command

Drive sends

Notes

CC3

-

Set running current to 3.0 amps

CI

CI=1.5

CI automatically set to 1.5 amps along with CC3 command

CI1

-

Set idle current to 1.0 amps