Casella CEL CEL-414 User Manual

Page 51

Advertising
background image

AC (all except CEL-493/3):

Conditioned signal,
typically 7.75 V RMS
for FSD.
Recommended imped-
ance of any connected
device (including
interconnecting cable)
>10 kΩ and <50 pF.
Consult CEL about
cables for use with
equipment not
manufactured by CEL.

DC (CEL-493/3 only):

Logarithmic signal
48 mV/dB nominal, not
exceeding 5 V,
18 ms rise time and
0.5 ms decay time for
fast, slow and impulse,
rise and decay times
for peak signals
depend upon the
impedance of connec-
ted equipment.
Recommended
impedance of output
device >10 kΩ.d

DC (all except CEL-493/3):

Logarithmic signal
48 mV/dB nominal, not
exceeding 5 V,
125 ms rise time and
decay time for fast,
1 s rise time and decay
time for slow,
35 ms rise time for
impulse signals,
0.1 ms rise time for
peak signals,
Typically <50 ms
decay time for both
impulse and peak
signals,
Recommended
impedance of output
device >10 kΩ.

Analog inputs:

AC:

22.5 V

pk-pk

via

CEL-216 Line Input
Adaptors for Type 1
instruments (or
CEL-316 for Type 2),
Recommended

Table 5: Typical noise floor in pass bands CEL-266/3 [and CEL-328/2]

Centre

20 (Lo)

20 (Lo)

50 (med)

80 (Hi)

Freqency

A-weighted Linear

A + Lin

A + Lin

dB

dB

dB

dB

31.5

Hz

8 [5]

16 [8]

<39 [35]

<69 [65]

63.0

Hz

8 [5]

15 [10]

<39 [35]

<69 [65]

125.0

Hz

8 [5]

13 [12]

<39 [35]

<69 [65]

250.0

Hz

10 [7]

12 [13]

<39 [35]

<69 [65]

500.0

Hz

10 [11]

11 [14]

<39 [35]

<69 [65]

1.0

kHz

11 [14]

11 [14]

<39 [34]

<69 [64]

2.0

kHz

11 [16]

11 [16]

<39 [33]

<69 [63]

4.0

kHz

11 [17]

11 [17]

<39 [31]

<69 [61]

8.0

kHz

9 [16]

11 [18]

<39 [34]

<69 [64]

16.0

kHz

8 [13]

10 [19]

<39 [39]

<69 [69]

General CEL Sound Level Meters Handbook - Page 47

Advertising
This manual is related to the following products: