6 compactflash ™ cards, Sensus data logger – Casella CEL Nomad portable weather station User Manual

Page 54

Advertising
background image

It is to this port that a PC is usually connected in order to

program/interrogate the logger. The Sensus Logger is shipped from Casella CEL
with this primary command interface set to the following parameters:

Default parameters - Primary command interface
Baud rate

9600

Data bits

8

Parity

None

Stop bits

1

Handshake

None

All of these parameters may be changed using commands built into the logger
software interface.

The same command channel is also accessible from the connector

array. This time the interface signals appear on a 5-way spring terminal block.

This is of use where power and communication are supplied via a fixed

cable. The communications signals can be connected to a 9-way D-type
connector without the need to prepare the ends of the cable.

The pin connections for the RS 232 Command - Spring terminal

connector are as follows.

Pin

Assignment

1

Ground

2

Transmit data (out)

3

Receive data (out)

4

DTR (out) (linked internally to 7)

5

CTS (in)

7.5.2

Sleep Mode

When enabled, the logger will conserve power by switching off the RS 232
interface circuitry after a period of inactivity. While in this state the logger is still
able to detect the arrival of characters over the command interface and when
the first character arrives, the logger will waken and switch on the RS 232
interface again.

However this can mean that the logger may not interpret the

first character correctly.

7.5.3

Display

The Sensus Logger supports a 2-line by 20-character LCD module, 4 keys and a
buzzer. The LCD incorporates a back light that is lit for a few seconds on every
key press.

The display provides information about the internal status of several of

the key functions of the logger, these include date/time, active channels and
logging summary.

The LCD will always show something, unless the logging period has

been set to one minute or more, whereupon an internal power-save function
comes into effect and the LCD becomes blank, switching on again only as data is
logged.

Should the LCD be blank, it can be reactivated immediately (without

having to wait for a log cycle) by pressing any one of the front panel keys.

7.6

CompactFlashCards

CompactFlash memory cards are lightweight, small form factor, removable data
storage devices built around reliable Flash storage technology.

The Sensus Logger’s integrated CompactFlash slot allows it’s storage

capacity to be increased and in addition provides a compact and reliable method
of transporting data from site for analysis. The slot is located on the right-hand

Sensus Data Logger

Page 54 of 68

NOMAD Portable Weather Station

Users Handbook