Casella CEL Sensus data logger unit User Manual

Page 40

Advertising
background image

Programmable threshold

Programmable data value (0/1, -1/+l)

Instrument Channel:

The unit has a single channel available to accept digital data

(via RS-232) from external instruments, including CEL sound level

meters. (Other instruments on request, development fee).

Passive Channels:

Software derived channels, which hold values entered via the user

command interface.

Can record manual readings and values from external automated

equipment.

Note:

The number of passive channels available depends on the number of

unassigned data channels.

Data Channels:

64 data channels under software control to read:
Analogue

Digital

Pulse counter

Frequency

Instrument

Passive

Other data channels

Alarms
Data channels allow further manipulation of the available data before

it is logged or displayed. Each channel includes:
Description (Free text, ‘Air temperature’)

Units (Free text, ‘Degrees C’)

Display format (How the number is represented) Signed, fixed width,

leading zeros.
Eight-term polynomial (For scale, offset and linearisation of raw data)
Y = C + M1 *X + M2*X^2 ...+ M7*X^7
Data process function: including minimum hold, maximum hold,

average, vector average.

Analog Outputs:

2 analogue outputs derived from PWM (pulse width modulation)

signals. Any of the data channels can act as a source for the output

value.
Output voltage (0 to 5 V)

Resolution (10-bit : 1 in 1024)

Update period (50 mS)

Specification

Page 40 of 44

SENSUS Digital Data Logger -

Users Handbook