LOGGING

By default, the Sensus logs data to its internal record store at an interval

specified by the user. If the logger detects the presence of a compatible

CompactFlash™ card, it automatically uses this instead. When the card is

removed, the logger reverts to using its internal store. For information on the

use of CompactFlash™ cards please refer to Section 8 on CompactFlash™.

4.1

Log Rate

The logger operates with two logging rates, one normal rate and one fast

rate. Switching between these two rates is handled automatically by the

alarm system. For further information please refer to Section 12 on Alarms.

Both logging rates can be set to any value between 5 seconds and

24 hours.

4.2

What Gets Logged ?

Any data channel that has its “log active” flag set will be included when the

next log event occurs. Logging globally can be disabled/enabled by changing

the “log active” flag held in the logging configuration. This allows logging to

be suspended temporarily without changing all the channel flags.

4.3

Internal Capacity

The Sensus Logger has 512 kBytes of internal Flash storage available to hold

logged information. This store is updated in a first-in-first-out manner so that

the earliest records are always being replaced with the newest ones. While

this means the logger will never stop recording data, only a set period of time

will remain available for collection at any time.

The number of records held and the period of time covered by the

internal store depend on both the number of channels being logged and the

logging interval.

The following equations let the user calculate the record capacity

and the store duration.

These equations should be used only as a guideline as the logging interval

may change during operation, especially if the “fast mode” option has been

enabled in the alarms.

Some example internal result capacities are shown in Table 2.

524288

7

4

+

=

(

)

Re

Channels x

cord Capacity

Re cord Capacity x Logging Interval

Store Duration

=

Logging