Recall:

Recalls the settings of a stored preset.

Store:

Stores the current amplifier settings to the selected

preset memory.

Clear:

The selected preset memory is cleared and «(empty)»

is displayed on the «Name» button.

Note: Choosing one of these functions, a corresponding

confirmation dialog will be issued to allow either confirmation

of the selection or to cancel the action by selecting the Back

button ( ).

9.5.6. Scope

The «Scope» function allows basic signal monitoring of the

amplifier's output voltage (full color) and output current (light

color).

Select
A U, I

Output voltage and current of channel A.

B U, I

Output voltage and current of channel B.

C U, I

Output voltage and current of channel C.

D U, I

Output voltage and current of channel D.

All U

Output voltage of all channels.

All I

Output current of all channels.

All U, I

Output voltage and current of all channels.

Y scale
Scale of the measuring values in FS (Full Scale). 1.0 FS represents

the maximum output voltage or output current.

Application examples
The scope function is a useful tool for ...:

determining the signal quality.

determining a phase shift between the channels.

getting a rough impression of the crest factor.

checking the output channels (e.g. no output current

displayed Þ the connector cable may be interrupted or

no loudspeaker is connected.

checking the power amplifier (e.g. no output voltage

displayed).