80

Amp. ground fault

Amp. ground fault (status

%04X, err %04X,

%5.1dV, %5.1dV)

Ground fault

External: Wrong speaker

connection

Error in speaker wiring,

ground connection

81

Amp. supply fault

Amp. supply fault 5 V

(status %04X, err %04X,

%4.1dV)

Amp. 5 V supply voltage

fault

Amp.

Amp. defect

84

Amp. supply fault

Amp. supply fault 12 V

(status %04X, err %04X,

%4.1dV)

Amp. 12 V supply

voltage fault

Amp.

Amp. defect

85

Amp. supply fault

Amp. supply fault GND

(status %04X, err %04X,

%4.1dV)

Amp. gnd voltage fault

Amp.

Amp. defect

86

Amp. supply fault

Amp. supply fault 230V

(status %04X, err %04X,

%4.1dV)

Amplifier rail voltage

fault

Amp., SMPS

Amp. overcurrent, Amp.

or SMPS defect

88

Amp. I

2

C fault

Amp. I

2

C fault (status

%04X, err %04X)

Amp. internal

communication fault

Amp.

Amp. defect

90

Amp. DC fault

Channel '%c': Amp. DC

fault

Amp. detected DC

voltage output

Amp.

Amp. defect

91

Amp. overcurrent

Channel '%c': Amp.

output overcurrent

(power %uw)

Overcurrent on output

(External: Cabling)

Short circuit

92

Amp. temperature error

Channel '%c': Amp.

temperature error %d°C

(filter temp. %d°C,

power %uw)

Amp. temperature error

DSP

Software fault on DSP

93

Filter overtemp %d°C

Channel '%c': Amp. filter

over temperature %d°C

(power %uw)

Amp. over temperature

of output filters

Amp.

Poor cooling

94

Amp. clock fault

Channel '%c': Amp.

clock fault (%3dkHz,

power %uw)

Amp. clock fault

Amp.

Amp. defect

95

Amp. overtemp %d°C

Channel '%c': Amp.

overtemperature %d°C

(power %uw)

Amp. over temperature

Amp.

Poor cooling

96

Amp. temp sensor fault

Amp. temperature sensor

fault (A %d°C, B %d°C,

C %d°C, D %d°C)

Amp. temperature sensor

fault

Amp.

Amp. defect

99

Amp. temp warn %d°C

Channel '%c': Amp.

temperature warning %d

°C (power %uw)

Amp. temperature

warning

Amp.

Poor cooling

100

SMPS temp warn %d°C SMPS temperature

warning %d°C (power

%uw)

SMPS temperature

warning

SMPS

Poor cooling

101

Filter temp wrn %d°C

Channel '%c': Amp. filter

temperature warning %d

°C (power %uw)

Amp. temperature

warning of output filters

Amp.

Poor cooling

120

CAN open error

Could not open CAN

interface (error %d)

CAN interface open

error

DSP

DSP defect or software

error