d&b D80 User Manual

Page 81

Advertising
background image

Id

Error text

Eventlog text

Description

Location

Possible reasons

38

SMPS overcurrent %dA

SMPS Error: overcurrent

(I-peak %3dA, avg

%3dV, status %04X, err

%04X)

Mains overcurrent

(External: Power draw)

Heavy output load

39

SMPS error IAC %dA

SMPS error IAC (I-peak

%3dA, avg %3dV, status

%04X, err %04X)

SMPS fault

SMPS

SMPS defect

40

SMPS temp. sensor fault SMPS temperature

sensor fault (T1 %

+3d;T2 %+3d;T6 %

+3d;T7 %+3d)

SMPS temperature

sensor fault

SMPS

SMPS defect

41

SMPS DC undervoltage SMPS DC undervoltage

error (I-peak %3dA, avg

%3dV, status %04X, err

%04X)

Amplifier rail voltage not

reached

SMPS, Amp.

Amp. overcurrent or

SMPS defect

42

SMPS DC overvoltage

SMPS DC overvoltage

error (I-peak %3dA, avg

%3dV, status %04X, err

%04X)

Amplifier rail voltage

exceeded

SMPS

SMPS defect

43

SMPS supply error

SMPS supply error 15V

(I-peak %3dA, avg

%3dV, status %04X, err

%04X)

SMPS 15 V supply fault SMPS

SMPS defect

44

SMPS error off %dV

SMPS error: power

supply went

unexpectately off (avg

%3dV, peak %3dV,

status %04X, err %04X)

SMPS went

unexpectately off

SMPS, External: Mains

Mains voltage is/was

too low or SMPS defect

45

Amp. comm. error

Amp. communication

error (status %04X)

Amp. communication

fault

DSP, Amp.

DSP or Amp. defect

46

Amp. firmware is too old Amp. firmware version

%4.2d is too old,

required is %4.2d

Amp. firmware version is

older than required

Amp.

Amp. software error

50

Invalid device para

Channel '%c': invalid

device parameters

(device ident %d)

Invalid device

parameters

DSP

Software error or wrong

device type detected

51

Invalid DSP prog %u

Channel '%c' : invalid

DSP program %d

DSP program invalid

DSP

Software error

52

DSP boot error

Channel '%c': DSP boot

error (DSP program %d)

DSP boot error

DSP

DSP or software error

58

DSP comm. error

Channel '%c': DSP

communication error

DSP communication fault DSP

DSP defect or software

error

59

Invalid setup data

Channel '%c': invalid

speaker setup (speaker

id %d, no. %d, err %d)

DSP invalid setup data

DSP

Software error

61

Invalid FIR filter %d

Channel '%c': invalid FIR

filter %d (file version %d)

DSP invalid FIR data

(External: FIR data file

invalid)

Software error

79

Amp. firmware mismatch Amp. firmware V%d.

%02d.%02d not suitable

for hardware ident %d

Amp. has wrong

firmware

Amp.

Amp. firmware does not

support the Amp.

hardware

d&b D80 Manual 1.9 en

81

Advertising
This manual is related to the following products:

10D, 30D, D20