15.2. Max. number of cabinets operated in parallel
The following table indicates the maximum number of cabinets

which can be operated in parallel by one amplifier channel in

order to be able to detect a failure of a loudspeaker component.

Note: The thresholds of the System check function defined by

the light blue area (–20 % ... +30 %) are also used by Load

monitoring to evaluate the system status. Therefore the values

in the table also apply to Load monitoring. If more cabinets

are operated in parallel, a correct supervision for single

component faults is not possible. This is of particular

importance for voice alarm and evacuation systems.

System

Failure mode

Single cabinet

disconnected

HF section of

single cabinet

Single HF/MF

driver

LF section of

single cabinet

Single LF driver

16C

3

3

-

1

-

24C

2

2

-

1

-

24C-CE

1

1

-

1

-

10AL/10AL-D

3

3

-

3

-

10S/S-D/A/A-D

3

3

-

3

-

12S/S-D

2

2

-

2

-

12S-SUB

3

-

-

3

-

18S/A-SUB

3

-

-

3

-

27S/A-SUB

1

-

-

-

1

4S

3

2

-

3

-

5S

3

2

-

3

-

8S

3

2

-

3

-

B1-SUB

1

-

-

-

1

B2-SUB

1

-

-

-

1

B4-SUB

2

-

-

2

1

B6-SUB

2

-

-

2

-

C3

2

2

1

2

1

C4-TOP

3

2

-

3

-

C4-SUB

3

-

-

3

-

C6/690

3

2

-

2

-

C7-TOP

3

2

-

3

-

C7-SUB

3

-

-

3

-

Ci-SUB

3

-

-

3

-

Ci45/60/90

3

2

-

3

-

Ci80

3

1

-

3

-

E0

3

2

-

3

-

E12/12-D

3

2

-

3

-

E12-SUB

3

-

-

3

-

E12X-SUB

3

-

-

3

-

d&b D80 Manual 1.9 en

78