12.1. Power supply
The device utilizes a switch mode power supply with active Power

Factor Correction (PFC) and automatic mains range selection.

The power supply is equipped with mains voltage monitoring,

overvoltage and undervoltage protection as well as an inrush

current limiter.

12.1.1. Active Power Factor Correction (PFC)

The active

Power Factor Correction provides a clean and highly

efficient sinusoidal current draw, thus providing highest

performance under adverse mains conditions or when very long

power cabling is necessary.

The power factor is above 0.9 for mains power consumption

values of 500 W or higher.

12.1.2. Automatic mains range selection

The automatic mains range selection enables the device to be used

with any mains supply worldwide without the need for manual

action.

High range

208 - 240 V AC

Low range

100 - 127 V AC

Nominal mains ranges

Behavior with fluctuating mains voltages
With mains voltages other than the nominal voltages specified

above, the device switches to the adequate mode for either

'Protection' or 'Operation'.

The voltage thresholds are dependent on the slope of the mains

voltage change.

Undervoltage

Undefined

Overvoltage

The Main Power Supply is switched off. In

undervoltage state, the auxiliary mains

supply for device control only operates to a

limited extend.

0

Ü

75

Ü

133

Ü

170

Ü

266

Ü

400

Undervoltage

Low range

Undefined

High range

Overvoltage

Protection

Operation

Protection

Operation

Protection

0

Þ

85

Þ

140

Þ

190

Þ

276

Þ

400

12.1.3. Mains voltage monitoring

The mains voltage and frequency are recorded by the power

supply and can be viewed on screen. Where voltages outside of

this range are present, a self-resetting protective circuit responds

quickly to isolate the internal Main Power Supply leaving only a

supervisory circuit running to monitor the mains voltage. The device

accepts mains voltages of up to 400 V AC

RMS

without damage to

the device in case of a missing neutral line or running phase to

phase.

12. Operation (Hardware references)

d&b D80 Manual 1.9 en

68