Speaker – d&b D80 User Manual

Page 59

Advertising
background image

Load monitoring setup
On the «System check» screen, selecting «LM setup» opens the

corresponding subscreen.

The «Load monitoring setup» menu provides all relevant

parameters for adjustment to the on-site requirements.

Load

monitoring

On/Off

Activates Load monitoring. The On/Off status

is also indicated on the System check and

Channel setup screens.

LM Period

The maximum time in detents of 20 sec. it

takes the system to detect a loudspeaker

malfunction. The intervals of the pilot signal

are derived from this parameter.

LM Threshold

Large signal threshold. When the output

signal exceeds this voltage level during the

measurement, the tolerance limits for this

particular measurement are increased in

order to compensate for the reduced

accuracy.

zMin

tolerance

Lower limit of the impedance window, which

is set to –20 % by default.

zMax

tolerance

Upper limit of the impedance window, which

is set to +30 % by default.

Dev.:

Relative deviation in percent in relation to the

reference values determined during

calibration.

10.8. Speaker
Selecting «Speaker» opens the Speaker setup subscreen which

enables the selection of loudspeaker setups for the applicable d&b

loudspeakers (depending on the selected output mode).

The setups available are arranged in two blocks, «Series» and

«Speaker».

Back ( )

The Back button provides two options:

1. The selection has not been confirmed by

tapping «OK» Þ Cancel:

Exits the subscreen and the previous

configuration remains active.

2. The selection has been confirmed by tapping

«OK»: Exits the subscreen.

Series

The bottom left of the «Series» Input field displays

the number of setups available while the bottom

right displays the actual name of the Series.

The list is in alphabetical order, the starting point,

however, is the Series currently loaded.

Selecting «(All)» provides direct access to all

setups available and the LINEAR setup.

d&b D80 Manual 1.9 en

59

Advertising
This manual is related to the following products:

10D, 30D, D20