A 2 –Installation


The digital audio toolbox b40 can be remote-controlled by means of parallel
GPI contacts.

use :

remote-controlled changeover of presets


connector:

D-SUB 15pin, female

Pin assignment of the connector :

Pin

Signal name

Functions

1

GPI1 in

Defined by d07 config

2

GPI2 in

Defined by d07 config

3

GPI3 in

Defined by d07 config

4

GPI4 in

Defined by d07 config

5

GPI5 in

Defined by d07 config

6

GPI6 in

Defined by d07 config

7

GPI7 in

Defined by d07 config

8

GPI8 in

Defined by d07 config

9

+ 5V

110

10

GPI1/GPI2 common

11

GPI3 common

12

GPI4 common

13

GPI5 common

14

GPI6 common

15

GPI7/GPI8 common

Shield

GND


Electrical specification:
GPI input

potential free by opto-coupler in line with

a current source


ON: +3.5…+30V between GPIx input

and GPx common

OFF: less then 1.5V between GPIx input

and GPIx common


For serial numbers S/N 182 and higher (HW Revision 2 and higher) the
polarity of the GPI inputs has been changed. to make use of the internal

ground based

auxiliary 5 V for "low active" switching.


ON:
-3.5…-30V between GPIx input

and GPx common

OFF : less then 1.5V betwee GPIx input

and GPIx common


Signal duration must be at least 50msec.

Note : An internal auxiliary voltage feed of +5V is available on pin 9
via a 110

resistor. Ground is available from the shield of the connector

only! When using the auxiliary voltage feed, there is no electrical isolation
given anymore and the risk to inject unwanted noise is high!

Important Note :

You must take care about the polarity of the external

voltage applied to the GPIs.

Wrong polarity

may

destroy electronic

components

and may

cause fire

inside the d07!

2.8

REMOTE
CONTROL

2.8.1

GPI REMOTE
CONTROL
(PARALLEL
REMOTE)

Advertising