Tally out – Junger Audio d07 - Digital Transmission Processor User Manual

Page 12

Advertising
background image

A 2 –Installation



The digital audio level processor d07 can transmit specific device statuses via
parallel Tally lines.

use:

monitoring of the d07 status


Connector :

D-SUB 25pin, female


Pin assignment of the connector :

Pin

Signal name

Functions

1

Tally 1 normally closed

2

Tally 1 normally opened

Defined by d07 config

3

TALLY 2 common

4

Tally 3 normally closed

5

Tally 3 normally opened

Defined by d07 config

6

TALLY 4 common

7

Tally 5 normally closed

8

Tally 5 normally opened

Defined by d07 config

9

Tally 6 common

10

Tally 7 normally closed

11

Tally 7 normally opened

Defined by d07 config

12

TALLY 8 common

13

+ 5V

110 Ohm

14

TALLY 1 common

15

Tally 2 normally closed

16

Tally 2 normally opened

Defined by d07 config

17

TALLY 3 common

18

Tally 4 normally closed

19

Tally 4 normally opened

Defined by d07 config

20

TALLY 5 common

21

Tally 6 normally closed

22

Tally 6 normally opened

Defined by d07 config

23

TALLY 7 common

24

Tally 8 normally closed

25

Tally 8 normally opened

Defined by d07 config

Shiled



Electrical specifications:

GPO (Tally)

potential free relay contact

common / normally closed / normally opened

24V - 1A

125V - 0,5A

P

max

= 62,5VA

Note : An internal auxiliary voltage feed is available on pin 9 via a 110Ohm
resistor. Ground is available from the shield of the connector only!
When using the auxiliary voltage feed, there is no electrical isolation given
anymore and the risk to inject unwanted noise is high!

2.8.2

TALLY OUT