Input voltage configuration, User-supplied logic power (internal) – Adept SmartMotion User Manual

Page 32

Advertising
background image

Chapter 2 - System Installation

32

Adept SmartMotion Installation Guide, Rev. C

Input Voltage Configuration

See “sMI6 Digital Input Logic Voltage Configuration” on page 21.

Output Current Requirements (MP6-M, HPE and BR, External)

The digital outputs (HPE and BR) on the MP6-M are optically-isolated via Opto-22
modules. (Therefore, the output specifications for the MP6-M are different than the
MP6-S.) Select an appropriate plug-in single-channel module from the “Generation 4”
(G4) range manufactured by Opto-22. (Compatible modules are also made by other
manufacturers.)

Modules are available for various external voltages to suit the user’s equipment, including
12V DC and 24V DC, and 110VAC and 230VAC. See

Table 2-3

for specifications of some

commonly-used modules. (See the manufacturer’s documentation for any parameters or
module types not listed.) You must provide logic-power to connect to and from the
Opto-22 modules. The logic input current required depends on the number, voltage, and
type of Opto-22 modules.

The Opto-22 DC output modules can each supply from 0.5 to 3 Amps to the user’s
external equipment. The total current actually required for outputs will depend on the
user-supplied external equipment (relays, solenoids, limit switches, etc.).

User-Supplied Logic Power (Internal)

The Opto-22 opto-isolator modules also require logic voltage to interface with the Adept
sMI6 module. This voltage must be provided by the user at the PWR terminals. The power
supply voltage should be the same as the logic voltage rating of the Opto 22 output
module. For example: 5V logic voltage Opto 22 requires a 5V logic user-supplied power
supply. Use of shielded, twisted-pair cable is recommended. Allow 12mA per output
channel (a total 0.1A for 7 modules) for each MP6-M.

Table 2-3. Digital Output Specifications for HPE and BR (Opto-22 module, typical)

Opto-22 module type

G4ODC5

G4ODC5A

G4OAC5

G4OAC5A

Operating voltage range

5 - 60 VDC

5 - 200
VDC

12 - 140
VAC

24 - 280
VAC

Current rating @45°C ambient

@70°C ambient

3 A
2 A

1 A
0.55 A


1.5 A


1.5 A

Output voltage drop maximum

1.6 V

1.6 V

1.6 V peak

1.6 V peak

Off-state leakage @max voltage

1 mA

1 mA

5 mA rms

a

a

At 60 Hz, 140VAC

5 mA rms

b

b

At 60 Hz, 280VAC (2.5 mA rms at 60 Hz, 120VAC)

Turn-on time (hardware), max

c

c

The software scan rate depends on Servo software, and is currently 1 ms.

50 µs

100 µs

1/2 cycle

1/2 cycle

Turn-off time (hardware), max

c

50 µs

750 µs

1/2 cycle

1/2 cycle

Logic voltage range (V

cc

)

2.4-8 VDC

2.4-8 VDC

4-8 VDC

4-8 VDC

Logic input current

12mA@5V

12mA@5V

12mA@5V

12mA@5V

Advertising