Adept SmartMotion User Manual

Page 34

Advertising
background image

Chapter 2 - System Installation

34

Adept SmartMotion Installation Guide, Rev. C

Table 2-4. MP6-M Connector Terminal Assignments (Typical, 1 of 6)

Pin

Signal

Abbrev.

Description

Signal

Type

Default Mode of

Operation

1

OT+

Overtravel(+)

input

Open on overtravel
(configurable using
SPEC program)

2

(Connected to terminal 3)

a

a

Pins 2 and 3 are connected to each other to help you connect a normally-closed switch in
series, if you have separate OT signals from the limit switches at each end of the axis. Use
them if you need, otherwise make no connection.

3

(Connected to terminal 2)

a

4

OT–

Overtravel (return)

return

5

HM+

Home Switch(+)

input

Closed at home
(configurable using
SPEC program)

6

HM–

Home Switch (return)

return

7

BR+

Brake Release (+)

output

Closed in brake
released condition (not
configurable)

8

BR–

Brake Release (return)

return

9

SHD

Shield

shield

——

Table 2-5. MP6-M Opto Power (Logic) Connectors (one per MP6-M)

Pin

Signal

Abbrev.

Description

1

+PWR

If using Opto-22 G4ODC5 or G4OAC5 series modules: 5V.

2

RTN

Common (return) for the above voltage

3

SHD

Shield for power cable

4

GND

Ground for all MP6-M shield connections. Connect this to
your ground point.

Advertising