Inside vertical installation with roof termination – Avalon Firestyles 900 PI-1992 User Manual

Page 12

Advertising
background image

PAGE 12

FIGURE 6

The exhaust vent termination on either vertical or horizontal installations shall be located as follows:

A minimum of 4 feet (1219 mm) below or beside and a minimum of 1 foot (305 mm) above any door
or window that opens, or any opening into a building.

A minimum of 2 feet (610 mm) from any adjacent building.

A minimum of 7 feet (2134 mm) above grade, when located adjacent to public walkways.

A minimum of 2 feet (610 mm) above grass, plants or other combustible surfaces.

INSIDE VERTICAL INSTALLATION

WITH ROOF TERMINATION

NOTE: FOR STANDARD OR CORNER INSTALLATION, STANDARD INSTALLATION SHOWN.

PELLET VENT

NON-COMBUSTIBLE
MATERIAL TO
EXTEND UNDER TEE

6" MIN.

(152mm)

OPTIONAL

3" MIN. (76MM)