Care & maintenance instructions (cont.), J. convection fan (cont.), K. chimney system – Avalon Firestyles 900 PI-1992 User Manual

Page 38

Advertising
background image

PAGE 38

CARE & MAINTENANCE INSTRUCTIONS (Cont.)

J. CONVECTION FAN (Cont.)

With the right side panel open, disconnect the two black
power leads coming from the motor. These two wires
must be connected to the convection fan during assembly,
but their orientation does not matter.

Take a 7/16" socket or wrench and remove the single bolt
located at the top of the convection fan.

The convection fan can now be pulled out of the unit for
cleaning and servicing. With the convection fan removed,
check the gasketing that insulates the connection between
the convection fan and the appliance. If the gasket has
deteriorated, replace. Follow directions in reverse order to
re-attach the convection fan.

Once the convection fan is removed, place it so the impeller blades are facing up. Check the impeller blades for any
damage and replace if necessary. Use a vacuum cleaner or brush to clean away any flyash that may have accumulated.
Lubricate the convection fan bearings by dropping two drops of light machine oil into the two holes located on the outward
side. Over-oiling can damage your fan.

K. CHIMNEY SYSTEM

Check the chimney system for soot and creosote build-up, and have it cleaned by a certified chimney sweep if necessary.

Wind/Rain Cap

Factory-Built Chimney Sections

Tee with Clean Out Cover

Attachment to
Pellet-Burning Appliance