Care & maintenance instructions (cont.), I. exhaust fan (cont.), J. convection fan – Avalon Firestyles 900 PI-1992 User Manual

Page 37

Advertising
background image

PAGE 37

CARE & MAINTENANCE INSTRUCTIONS (Cont.)

I. EXHAUST FAN (Cont.)

At this time you should also clean away any flyash that is on or in the exhaust housing and check to make sure the flow
switch nipple is not clogged or dirty. See the illustration below for reference.

Exhaust Housing (clean any flyash)

Check Silicone Seal

Flow Switch Nipple (Make sure it
is not clogged - Check both ends)

Oil Bearings Through These
Two Holes (2 drops each)

Prior to replacing the fan assembly, check that the silicone seal at the fan and exhaust tube. If fractured, use Type RTV 500
degree silicone sealant to reseal the joint.

J. CONVECTION FAN

Open the right side panel by taking a standard screwdriver and turning the three screws located on the right side one-half
turn counter-clockwise.

These screws are actually cogs that hold the panel in place, and only need to be turned slightly to release. Then swing the
panel back on the hinge located on the very back of the left side.

To re-attach, use a screwdriver to turn the screws one-half turn while pressing them against their sockets. See the
illustration in the exhaust fan section for reference.

Control Box

Convection Fan

Convection Fan
Electrical Leads

Combustion Air Duct

Electrical Leads
From Control Box
to Switch Box

Hopper

Advertising