Avalon Firestyles 900 PI-1992 User Manual

Page 14

Advertising
background image

PAGE 14

The exhaust vent termination on either vertical or horizontal installations shall be located as follows:

A minimum of 4 feet (1219 mm) below or beside and a minimum of 1 foot (305 mm) above any door
or window that opens, or any opening into a building.

A minimum of 2 feet (610 mm) from any adjacent building.

A minimum of 7 feet (2134 mm) above grade, when located adjacent to public walkways.

A minimum of 2 feet (610 mm) above grass, plants or other combustible surfaces.

VERTICAL INSTALLATION INTO EXISTING

FACTORY BUILT CHIMNEY

FIGURE 8

NOTE: FOR STANDARD OR CORNER INSTALLATION, STANDARD INSTALLATION SHOWN.

6" Min.

(152mm)

Non-Combustible
Material To Extend
Under The Tee

Optional
Combustion Air
Intake With 90˚
Elbow Or Hood

Tee With
Clean Out Cover

Pellet Vent

3" Min. (76mm)

Pellet Vent To Factory
Built Adaptor Required

Keep Clearance Specified
By Factory Built Chimney
Manufacturer

24" Min. (610mm)

OPTION 2. Firestop With
3" (76mm) Clearance

OPTION 1. Wall Or
Ceiling Thimble

Flashing