Avalon Firestyles 900 PI-1992 User Manual

Page 23

Advertising
background image

PAGE 23

INSERT INSTALLATION INTO EXISTING

MASONRY FIREPLACE

OPTIONAL
OUTSIDE
AIR INTAKE

0" MIN.
(0mm)
FROM
FRONT
OF INSERT

NON-COMBUSTIBLE
MATERIAL

4" MIN. (102mm)

6" MIN. (152mm)

OUTSIDE COMBUSTION
AIR INTAKE

NOTE: Masonry fireplace installations require a direct connection or positive (complete reline) connection to the chimney

flue. With a direct connection a block-off plate made of metal or other non-combustible material (i.e. Kaowool or
high temperature fiberglass insulation) must be used at the damper location and sealed airtight. The singlewall
pipe or flexible liner must extend past the block-off plate or insulation by one (1) foot (305 mm) or to the first flue
tile if the chimney has a tile lining.

With a positive connection, the block-off plate at the damper location is optional, but a sealed cover plate is
required at the top of the chimney. A positive connection (complete reline) is recommended for ease of cleaning.

3" STAINLESS STEEL
SINGLE
WALL PIPE OR
FLEXIBLE
LINER IS REQUIRED;
REFER
NOTE BELOW.

SEE NOTE
BELOW

WIND / RAIN CAP

POSITIVE CONNECTION
(FULL RELINE)

SINGLE WALL TEE
CAN BE USED AS AN
OPTION

12" DIRECT CONNECTION
TERMINATION

AIR INTAKE OPTIONS

FIGURE 24

HEARTH
REQUIREMENT