Nsert, Nstallation – Avalon Firestyles 900 PI-1993 to 1996 User Manual

Page 22

Advertising
background image

P

AGE

22

I

NSERT

I

NSTALLATION

(C

ONT

.)

Exhaust Tube Specifications

The Avalon 900 PI is shipped with a vertical exhaust tube, but it can be adjusted to vent
horizontally (i.e., for built-in installations using a horizontal vent). To vent horizontally, unlatch
the upper and lower clips on the right side of the insert (remove the locking pins first), and
remove the exhaust tube and vertical exhaust extender. Discard the vertical exhaust extender.
Attach the exhaust tube with the lower clip, making sure the lower gasket is properly aligned,
and re-insert the locking pin.

Upper Clip

Exhaust Tube

Lower Clip

Vertical Exhaust Extender

Attach the exhaust
tube to the lower clip

Discard the vertical exhaust extender

Unlatch both clips

Locking

Pin

The illustration below details the exhaust tube location for the vertical and horizontal exhaut tube
configuration.

2 5/8"

1 3/4"

Center

of Stove

8"

19"

2 1/2"

Exhaust Tube Location:

Advertising