Tove, Nstallation – Avalon Firestyles 900 PI-1993 to 1996 User Manual

Page 9

Advertising
background image

S

TOVE

I

NSTALLATION

(C

ONT

.)

P

AGE

9

Pellet Vent Installation Options

¥

Minimum 3" clearance to any combustible

¥

No more than 180

o

of elbows (two 90

o

elbows, or two 45

o

& one 90

o

elbow, etc.)

NOTE: The Center Flue Adapter is the same as a 90

o

elbow.

¥

Maximum 33' rise if vertical only

¥

Maximum 10' length if horizontal only

¥

Maximum 10' horizontal length if vertical rise is 25' or less

¥

Maximum 4' horizontal length if vertical rise is 30' to 25'

¥

Do not connect the pellet vent to a vent serving any other appliance or stove

3" Minimum

See maximum

vertical rise

Type "L" Vent

Approved

thimble

Support
bracket

every 5'

See maximum

horizontal length

Joints must be

sealed and

screwed together

See "Pellet Vent

Termination"

Maximum

180 of
elbows

Floor

protection

under "Tee"

Installing the Pellet Vent

¥

Pellet vent connections must be screwed together with sheet metal screws and
sealed airtight with 500

o

F. RTV silicone

¥

The pellet vent connects to the exhaust
vent 5 3/4" from the center of the stove and
the distance listed below for the type of
legs or pedestal used (see the illustration to
the right):

Pedestal

13 1/8"

Brass Legs

9 3/4"

Cast Legs

9 3/4"

Black Legs

8 3/8"

Center Line

5 3/4"

See the Table

Exhaust Vent
(3" Inside
Diameter)

Advertising