Avalon Firestyles 900 PI-1993 to 1996 User Manual

Page 8

Advertising
background image

P

AGE

8

S

TOVE

I

NSTALLATION

(C

ONT

.)

F

LOOR

P

ROTECTION

R

EQUIREMENTS (See the illustration on the previous page)

The heater must be installed with floor protection that meets the following requirements:
¥

Made of a non-combustible material at least .018" thick (26 gauge)

¥

Extend under and 2" to each side of a chimney "Tee" if one is used

D

Must extend 6" in front of the heater (measured from door opening)

E

Must cover the area underneath the heater and 0" to each side ( Min. 24 5/16" wide)

F

Must cover the area underneath the heater and 0" to the rear (Min. 27 1/2" deep)

A

LCOVE

I

NSTALLATION

R

EQUIREMENTS

Whenever the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is
considered an alcove installation. Because of the reduced height, the special installation
requirements listed below must be met.
¥ Minimum height is 60"

¥ Minimum width is 42 5/16"

¥ Maximum depth is 48"

¥ Minimum clearance of 9" on each side and 3" on back

Backwall

Sidewall

Sidewall

9"
Min.

9"
Min.

3" Min.

Horizontal or Vertical Exterior Pellet Vent

Vertical
Pellet Vent

3" Min.

42 5/16" Min.

48"
Max.

60" Min.

Horizontal
or Vertical
Exterior
Pellet Vent

Vertical
Pellet Vent

3"
Min.

P

ELLET

V

ENT

R

EQUIREMENTS

Pellet Vent Type

¥

Must be Type "L"(except for masonry fireplace installations) - or - connect the
vent to a factory built type "A" chimney (adapter required)

¥

If the pellet vent is over 15' in total vertical length use 4" diameter (use adapter)

¥

If the pellet vent is over 4' in total horizontal length use 4" diameter (use adapter)

¥

If the heater is installed at an altitude over 4000' use 4" diameter (use adapter)

¥

Otherwise, use 3" or 4" diameter

¥

Follow the manufacturer's installation instructions for precautions required for
passing vent through a combustible wall or ceiling (i.e. use an approved thimble).

¥

Must have a support bracket every 5' of pellet vent when exterior