Nsert, Nstallation – Avalon Firestyles 900 PI-1993 to 1996 User Manual

Page 27

Advertising
background image

I

NSERT

I

NSTALLATION

(C

ONT

.)

P

AGE

27

H

Install the panels and brass trim to complete the installation. Included with the floor
shield kit are two pairs of side panels. The set that are flat are used, the bent pair can be
discarded. Attach the side panels to the side bays by placing them with the magnetic strip
side up against the side bay. Read the section "Operating the Heater" prior to plugging in
the insert and operating.

3" Minimum

Type "L" Vent

Flashing

3" Clearance

Approved

Ceiling Support

Outside Air

Framing

Wall Covering

Floor Shield

Top Panel
(3/8" space
between top
panel and wall
covering - do
not seal)

Floor covering must be

removed under insert

2'

Min.

If the termination is below the eave,

it must maintain a 2' clearance

1'

Min.

Approved

Wall

Thimble

3"

Min.

Approved thimble

Joints must be

screwed together

and sealed

Support
bracket

every 5'

3"

Min.

12"

Min.

See the
notes to
the left

VERTICAL INSTALLATION*

HORIZONTAL INSTALLATION*

* FOR A FULL LIST OF PELLET
VENT REQUIREMENTS, SEE
THE SECTION "PELLET VENT
REQUIREMENTS" IN THE
PELLET STOVE INSTALLATION
PORTION OF THIS MANUAL
(PAGES 8 THROUGH 10).

2' Min.

3/8" Space

(Do not seal)

Joints must be

screwed together

and sealed

Optional

vertical exterior
pellet vent route

Advertising
This manual is related to the following products: