Problem:

Possible Cause:

Don't Call for Service

Until You:

Heater won't start

(Operating light won't
turn on)

Heater not plugged in
Power button not turned "ON or start button pressed
Power supply cut
Fuse blown

Plug the heater in
See "Starting Your Heater"
Check household fuse/breaker
See "Fuse Blown" below

Firepot overfills on startup

Fire starter was lit with the BURN RATE on "HIGH"
Fire starter did not fully ignite
A

IR

C

ONTROL

was not pulled out after the BURN RATE

was set to "HIGH"

See "Starting Your Heater"
See "Starting Your Heater"

See "Starting Your Heater"

Fire starter extinguishes

soon after lighting

Heater was not turned on and the start button pressed
A

IR

C

ONTROL

was pulled all the way out while the fire

starter was just starting to burn

See "Starting Your Heater"

See "Starting Your Heater"

Lazy and dark orange

flame with black smoke

A

IR

C

ONTROL

is set too low

Firepot is plugged
Pellets are bad
Exhaust ducts are clogged
Air leak
Exhaust system is clogged

See "Operating Your Heater"
See "Check the Firepot"*
See "Poor Quality Pellets" below
See "Clean the Exhaust Ducts"*
See "Air Leaks" below
See "Exhaust Blower "*

Exhaust is smoky, but the

flame is okay

Heater was just started
Pellets are bad

This may occur and is not unusual
See "Poor Quality Pellets" below

Firepot overfills with

pellets

A

IR

C

ONTROL

is too far in

Firepot is plugged
Air leak
Exhaust ducts are clogged
Exhaust system is clogged

See "Operating Your Heater"
See "Check the Firepot"*
See "Air Leaks" below
See "Clean the Exhaust Ducts"*
See "Exhaust Blower"*

Pellets not feeding

Auger not primed
Pellets have run out
Power button not turned "ON or start button pressed
Power supply cut
Fuse blown
Auger flight jammed
Power outage
Pellet Vent Blocked

See "Starting Your Heater"
Refill hopper with pellets
See "Starting Your Heater
Check the household fuse/breaker
See "Blown Fuse" below
See "Jammed Auger" below
Wait until power is restored
See "Safety Features" below

Smoke smell in room

(Do not unplug, flip the
POWER switch to "OFF")

Momentary power outage
Flue not sealed
Automatic safety feature has shut off stove
Flue system on insert version not fully sealed

This is normal - see "Safety Features"
See "Installation Instructions"
See "Safety Features" below
See "Installation Instructions"

Heater turned off when

hopper is full

Power outage
Automatic safety feature has shut stove off
Auger jammed

See "Safety Features"
See "Safety Features"
See "Jammed Auger" below

Fire goes out on low burn.

A

IR

C

ONTROL

too far out

Air leak

See "Operating Instructions"
See "Air Leaks" below

Auto-Ignition System does

not start the heater.

Burn Rate set too low
A

IR

C

ONTROL

in too far

See "Starting Your Heater"
See "Operating Your Heater"

* In the section "Maintenance Instructions" starting on page 33.