Basler Electric BE1-851 Modbus Protocol User Manual

Page 52

Advertising
background image

3-14 BE1-851

Modbus

Protocol

9289900992 Rev F

Bit 4 - Output 4 Status
Bit 3 - Output 3 Status
Bit 2 - Output 2 Status
Bit 1 - Output 1 Status
Bit 0 - Output A Status


41287

Target Mask MSBs

BM(16)

Read

and

Write:

Bit 15 - BF
Bit 14 - 162
Bit 13 - 62
Bit 12 - 50TQ
Bit 11 - 50TN
Bit 10 - 50TC
Bit 9 - 50TB
Bit 8 - 50TA
Bit 7 - Spare
Bit 6 - Spare
Bit 5 - Spare
Bit 4 - 150TQ
Bit 3 - 150TN
Bit 2 - 150TC
Bit 1 - 150TB
Bit 0 - 150TA


41288

Target

Mask

LSBs

BM(16)

Read

and

Write:

Bit 15 - Spare
Bit 14 - 362

Bit 13 - 262

Bit 12 - 51Q
Bit 11 - 51N
Bit 10 - 51C
Bit 9 - 51B
Bit 8 - 51A
Bits 7-0 - Spare

∗ 262 and 362 are available when style option 1 is V or W.

41291-94

Programmable

Screen

#1

ASC(7)

41295-98

Programmable

Screen

#2

ASC(7)

41299-302

Programmable

Screen

#3

ASC(7)

41303-06

Programmable

Screen

#4

ASC(7)

41307-10

Programmable

Screen

#5

ASC(7)

41311-14

Programmable

Screen

#6

ASC(7)

41315-18

Programmable

Screen

#7

ASC(7)

41319-22

Programmable

Screen

#8

ASC(7)

41323-26

Programmable

Screen

#9

ASC(7)

41327-30

Programmable

Screen

#10

ASC(7)

41331-34

Programmable

Screen

#11

ASC(7)

41335-38

Programmable

Screen

#12

ASC(7)

41339-42

Programmable

Screen

#13

ASC(7)

41343-46

Programmable

Screen

#14

ASC(7)

41347-50

Programmable

Screen

#15

ASC(7)

41351-54

Programmable

Screen

#16

ASC(7)

Read

and

Write:

Screen identifier. For example, the Output Status Screen would be 1.5.2