Basler Electric BE1-851 Modbus Protocol User Manual

Page 66

Advertising
background image

4-4 BE1-851

Modbus

Protocol

9289900992 Rev F

ASCII Command

Modbus

Registers

SG-SCREEN9=<menu screen>

41323-41326

SG-SGCON=<time> 40871
SG-TARG=<target list>,<reset Targ Logic>

41287-41290,41403-41408,41411-41416

SG-TRIG=<trip trigger logic equation>,<pu trigger
logic equation>,<logic trigger logic equation>

41355-41360,41363-41368,41371-41376,41379-
41384,41387-41392,41395-41400

SL-43=<mode> 42091
SL-143=<mode> 42092
SL-243=<mode>

42093

SL-343=<mode>

42094

SL-101=<mode> 42099
SL-150TN=<mode>,<block logic equation>

41573,41574-41579,41582-41587

SL-150TP=<mode>,<block logic equation>

41556,41557-41562,41565-41570

SL-150TQ=<mode>,<block logic equation>
(350TN, Sensing input “G”)

41590,41591-41596,41599-41604

SL-50TN=<mode>,<block logic equation>

41522,41523-41528,41531-41536

SL-50TP=<mode>,<block logic equation>

41505,41506-41511,41514-41519

SL-50TQ=<mode>,<block logic equation>
(250TN, Sensing input “G”)

41539,41540-41545,41548-41553

SL-51N=<mode>,<block logic equation>

41708,41709-41714,41717-41722

SL-51P=<mode>,<block logic equation>

41691,41692-41697,41700-41705

SL-51Q=<mode>,<block logic equation>
(151N, Sensing input “G”)

41725,41726-41731,41734-41739

SL-79=<mode>,<RI logic>,<Status logic>,<Wait
logic>,<Lockout logic>

43173,43174-43179,43182-43187,43190-
43195,43198-43203,43206-43211,43214-
43219,43222-43227,43230-43235

SL-62=<mode>,< ini logic equation>,
<block logic equation>

41844,41845-41850,41853-41858,41861-
41866,41869-41874

SL-162=<mode>,<ini logic equation>,<block logic
equation>

41877,41878-41883,41886-41891,41894-
899,41902-41907

SL-262=<mode>,<ini logic equation>,<block logic
equation> †

43234,43235-43238, 43243-43246, 43251-43254,
43259-43262

SL-362=<mode>,<ini logic equation>,<block logic
equation> †

43267, 43268-43271, 43276-43279, 43284-43287,
43292-43295

SL-BF=<mode>,<ini logic equation>,
<block logic equation>

41658,41659-41664,41667-41672,41675-
41680,41683-41688

SL-GROUP=<mode>,<D0 logic equation>,
<D1 logic equation>,<D2 logic equation>,
<D3 logic equation>,<auto logic equation>

42010,42027-42032,42035-42040,42043-
42048,42051-42056,42059-42064,42067-
42072,42075-42080,42083-42088,42011-
42016,42019-42024

SL-N=<name> 41465-41468

SL-VOA=<boolean logic equation>

42133,42134-42139,42142-42147,42150-42155,
42158-42163,42166-42171,42174-42179,42182-
42187,42190-42195

SL-VO1=<boolean logic equation>

42198,42199-42204,42207-42212,42215-42220,
42223-42228,42231-42236,42239-42244,42247-
42252,42255-42260

SL-VO2=<boolean logic equation>

42263,42264-42269,42272-42277,42280-42285,
42288-42293,42296-42301,42304-42309,42312-
42317,42320-42325

SL-VO3=<boolean logic equation>

42328,42329-42334,42337-42342,42345-42350,
42353-42358,42361-42366,42369-42374,42377-
42382,42385-42390

SL-VO4=<boolean logic equation>

42393,42394-42399,42402-42407,42410-42415,
42418-42423,42426-42431,42434-42439,42442-
42447,42450-42455

SL-VO5=<boolean logic equation>

42458,42459-42464,42467-42472,42475-42480,
42483-42488,42491-42496,42499-42504,42507-
42512,42515-42520

Advertising
This manual is related to the following products: