background image

3-20 BE1-851

Modbus

Protocol

9289900992 Rev F

47389-92

Current

Active

Logic

Scheme

ASC(8)

Read

Only:

Current active logic name.


47393

Reclose

Status

Read

only:

0

for

Off

1 for Timing reclose #1

2 for Timing reclose #2

3 for Timing reclose #3

4 for Timing reclose #4

5

for

Wait

6

for

Lockout

7

for

Reset

8

for

Timing

fail

9

for

Timing

reset


47394-95

Breaker Contact Duty Log - Phase A

FP

47396-97

Breaker Contact Duty Log - Phase B

FP

47398-99

Breaker Contact Duty Log - Phase C

FP

Read:

If Breaker Duty Type = Off or Maximum Breaker Duty = 0, reads undefined
floating point value of 0xFFFFFFFF. Otherwise, reads 0.00 to 200.00%.

Write:
0

to

200%


47400-01

Breaker

Operations

Counter

LI

Read

and

Write:

0 to 99,999


47410-11

Yesterday's Peak Demand Current - Phase A

FP

47415-16

Yesterday's Peak Demand Current - Phase B

FP

47420-21

Yesterday's Peak Demand Current - Phase C

FP

47425-26

Yesterday's Peak Demand Current - Neutral

FP

47430-31

Yesterday's Peak Demand Current - Neg-Seq

FP

Read only:

Any value (amps)

47412

Yesterday's Peak Demand Timestamp - Day

INT

47417

Yesterday's Peak Demand Timestamp - Day

INT

47422

Yesterday's Peak Demand Timestamp - Day

INT

47427

Yesterday's Peak Demand Timestamp - Day

INT

47432

Yesterday's Peak Demand Timestamp - Day

INT

Read

only:

Any value (days since 01/01/1984).


47413-14

Yesterday's Peak Demand Timestamp - Millisecond

LI

47418-19

Yesterday's Peak Demand Timestamp - Millisecond

LI

47423-24

Yesterday's Peak Demand Timestamp - Millisecond

LI

47428-29

Yesterday's Peak Demand Timestamp - Millisecond

LI

47433-34

Yesterday's Peak Demand Timestamp - Millisecond

LI

Read

only:

0

to

86,399,999

milliseconds.


47435-36

Today's Peak Demand Current - Phase A

FP

47440-41

Today's Peak Demand Current - Phase B

FP

47445-46

Today's Peak Demand Current - Phase C

FP

47450-51

Today's Peak Demand Current - Neutral

FP

47455-56

Today's Peak Demand Current - Neg-Seq

FP

Read only:

Any value (amps)