Audio channel descriptions

Input channel

A detailed block diagram of the Input channel may be found in the Appendix on

page 74.

The CDC FOUR can handle up to 48 mono mic/line inputs, divided into three

blocks of 16. The inputs to Channels 1 to 16 are on the rear panel; those for

Channels 17 to 48 are only available if the CDC RACK stagebox is in use.

The CAM and the TFT display are made active for a mic/line input when one

of the first three layers is selected (CHNS 1-16, CHNS 17-24, CHNS 33-48).

The active channel is that whose SEL button is illuminated. If no CDC RACK is

connected, the two buttons CHNS 17-32 and CHNS 33-48 will be inoperative.

Mic pre-amps
Mic/line inputs 1 to 16 are equipped with high-quality, low-noise mic pre-amps.

This design uses premium ICs and exhibits wide dynamic range and excellent

CMRR. The gain control operates in the analogue domain, and has a range of

0 to +60 dB.

Meters
The 10-segment LED bargraph meter shows either the pre-fade or post-fade

signal in the channel, as selected by the Pre/Post switch on the METERS screen

page. The sixteen fixed meters (below the mic pre-amp gain controls) change

source with layer selection, thus can be used to monitor stereo inputs, group

and Aux sends, etc., as well as mic/line inputs. When the ST CHNS VCA layer is

selected, the odd numbered meters show the left legs of the stereo channels, and

the even-numbered the right.

The lowest LED (coloured green) illuminates at -54 dB and can be considered

a “signal present” LED. The top three LEDs (coloured red) illuminate at -6 dB,

-3 dB and 0 dB respectively. Note that the 0 dB reference for these levels is

0 dBFS (digital clipping). Thus the input gain should be adjusted so that the top

LED never illuminates.