Cadac CDC four User Manual

Page 33

Advertising
background image

Revision 1 2012-13

CDC FOUR

33

VIN – enables an alternative compressor algorithm which makes the compressor

act like a leveller, modelling the sound of certain vintage compressors.

NOTE: Additional Compressor parameters are available from the Dynamics

Details screen page – see “Dynamics detail” on page 54.

Delay section:
DLY
– the CDC FOUR allows an adjustable delay to be inserted in each signal

channel. Range 0 to 100 ms. Default setting is zero.

DLY: IN - switches the delay circuit into the signal chain. Default is Out.

Dynamics/Delay Global:
BYP
- switches the complete dynamics section (gate, compressor and limiter)

and delay section in and out of the signal chain. Default is Out.

PST – the dynamics and delay sections can be pre- or post-EQ in the CDC FOUR.

Pressing PST inserts them after the equaliser. Default is Off (i.e., dynamics are

pre-EQ).

S

mS

DLY

IN

S

mS

+

-

+

-

+

-

+

-

20:1

1:1

LIM

THR

DLY

COMP

GATE

LVL

RAT

THR

THR

IN

IN

AUT

VIN

IN

IN

BYP

PST