10 - gerkin protocol, Test procedure – Cybex 625T Treadmill User Manual

Page 85

Advertising
background image

10 - Gerkin Protocol

Workout Overview
This workout was designed to predict the VO

2

max using the Gerkin protocol. This test is used by the

International Association of Firefighters to evaluate fitness level.

Note: This workout requires the user to wear a 5 KHz Polar

®

or compatible heart rate transmitter

belt.

The speed range of the workout includes walking speeds at 3 MPH then increases to 4.5 MPH or more
during the middle stages. It returns to 3 MPH during the cool down session.

Elevation is used during the second stage of the test. It starts at a 2% grade and can increase from
there.

Input information:
• Age
• Weight
• Gender
• Heart rate (5 KHz Polar

®

compatible wireless chest strap required)

Test procedure:

1. 3 minute warm-up at 0% grade, 3 mph.

2. Stage 1 – 1 minute, 0% grade, 4.5 mph. Walk or run. Heart rate is recorded during the last 15

seconds of each stage.

3. Stage 2 – 1 minute, 2% grade, 4.5 mph.

• Speed and grade increases now alternate. At odd numbered stages, speed increases by 0.5

mph. At even numbered stages, grade increases 2%.

• If heart rate is 85% or above, the stage is recorded, but the test continues for another 15 seconds

with no increase in grade or speed.

• If heart rate remains above 85%, the test is terminated, and the last stage number is entered.
• If heart rate falls to or below 85%, speed or gradient is increased on the next minute boundary.
• Once the 85% threshold is exceeded or makes it to the 11th minute, the evaluation is ended and

the final stage is entered.

4. 3 minute Cool-down – 0% grade, 3 mph.

5. Take heart rate and record one minute after the end of the test. (Taken as a final reading and to

monitor HR stabilizing).

Page 85 of 88

Cybex 625T Treadmill Part Number LT-23221-4 H

Advertising