Rf datalink, Test communications, Indicator status – Digi-Star RF DataLink Operators Manual User Manual

Page 30

Advertising
background image

RF DataLink

24

Test Communications

To access this screen select File, and then Test
Communications.

The option will allow you to test communications
with the EZ indicator.

In this screen you can select the EZ indicator to
communicate with and view that status of the
indicator.

Indicator Status

The status of the indicator is what information is in
the scales internal memory.

Example: If you send one load of 6 ingredients and 2 pens the status will show:
U0008D0000 This shows that there are 8 records in the scale memory of undone
information. As the operator completes each ingredient and pen the undone records will
then move to the done side. In order for the scale to send back complete data to RF
Datalink there cannot be any undone records in the memory. The status must show:
Example: U0000D0008 at this time the scale will then start to send back the completed
data.

If a load was sent to the EZ indicator that needs to be removed you have the ability to clear
the batches in that indicator by clicking on the “Clear Mixer” button. If the status is:
D9999U9999 this means that the scale is not in range or the scale is scrolling a message.
The scale must be in weighing mode: Net or Gross for the scale to be cleared. Select the
Get Feeding Status to refresh the status screen. Then select Clear Mixer.

You will have the same control in this screen as you would have at the indicator. You can
click on the keys and also send a text message to the indicator. The indicator will continue
to display the message until a key is press.