Digi-Star EZII Escape Computer Command Set User Manual

Page 30

Advertising
background image

EZII Escape Computer Command Set

30

D36 48 Rev G

November 30, 2009

6, 26

Transmit weight display whenever the displayed weight changes to a different value.

& 36

-

Same data format as setting 1.

7

Transmit comma delimited data which includes the basic weighing information 1 time per second.
-

Includes Gross Weight, display unit, weight tag (GR, M+, etc...), Total Rotation Count, Date
& Time with seconds.

-

Ends with a <CR>,<LF>. (Carriage Return- Dec. 13, Line Feed-Dec. 10).

Output example:
1 2 3 4

1234567890123456789012345678901234567890
" 280,LB,GR, 187,03JL03, 3:41:21"

8

Transmit comma delimited data which includes the basic weighing information once every 5
seconds.
-

Same data format as setting 7.

9

Selection #9 is reserved.

10

Transmit comma delimited data which includes the EID Tag Reader information once every 2
seconds.
-

Includes Gross Weight, display unit, weight tag (GR, M+, etc...), Date & Time.

-

Ends with a <CR>,<LF>. (Carriage Return- Dec. 13, Line Feed-Dec. 10).

-

For more details on data field format see “Send All EID Records Command” response
sw550/sw2600 format.

Output example:

1 2 3 4 5 6

123456789012345678901234567890123456789012345678901234567890123456789

" EID Data (right justified), 1400,LB,$,GR,08/12/03,14:09,C"

Checksum^

The Check Sum calculation is found at the end of this section.

11

Transmit comma delimited data which includes the "serial gross weight" 2 times per second.

See service Bulletin #31 for additional information about the “Serial Gross Weight”.

The serial gross weight data will be sent at 9600 Baud, 1 start bit, 7 data bits, 1 EVEN parity
bit and 1 stop bit on pin 2 (COM #1 Tx line) of a J904 or J905 Serial / Printer connector.

Please Note: This setting may not be available if a radio is installed in the indicator for
communications to a Cab Control or Datalink system.

-

Starts with < STX> (Start of TeXt - Dec. 2).

-

Six digit Serial Gross Weight “whole number” value (ie.1000 not 100.0).

-

"LB" or "KG" unit of measure.

-

Space character.

-

"SG" to identify Serial Gross weight.

-

The <ETX> (End of TeXt - Dec. 3) control character.

-

Checksum Character (C) value that includes all bytes starting after the <STX> up through,
but not including the <ETX>. The Check Sum calculation is found at the end of this
section.

-

Ends with a <CR> (Carriage Return- Dec. 13).

Advertising