3. General

All illustrations and details in these installation instructions are subject
to changes that are necessary to improve product performance without
prior notice.
The copyright of these instructions is the property of Flowserve. These
instructions are intended for Maintenance, Operating and Supervisory
personnel and contain regulations and drawings of a technical charac-
ter that may not, in full or in part, be copied, distributed, used without
authorisation for competitive purposes, or given to others.

!

It should be understood that Flowserve does not accept any liabili-
ty for instances of damage and/or malfunctioning incurred through
non-adherence to these installation instructions.

4. Transport, Storage

The mechanical seal and related equipment maust be transported and
stored in the unopened, original shipping box. The warehouse in which
the mechanical seals and related equipment are stored must be dry and
free of dust. Avoid exposing equipment to large temperature fluctua-
tions and radiation.
Parts or complete mechanical seals that have been dropped or other-
wise have been subjected to heavy impacts during transport must not
be installed.
An inspection by Flowserve or its appointed representative is strongly
advised.

If the machine is to be preserved with integrated mechanical

seal(s) the preserving medium must not impair the functions of

the mechanical seal(s) by e.g. fouling of the seal faces, hardening,
or swelling the secondary seals.

After a storage period of 3 years the mechanical seal must be inspect-
ed for its “as new” properties. This applies in particular to the seal
faces and secondary sealing elements. An inspection by Flowserve
becomes necessary.

!

The mechanical seal can in principle be transported with suitable
means like lifting accessories.

5. Equipment Check

5.

!

Follow plant safety regulations prior to equipment disassembly:

• lock out motor and valves.

• wear designated personal safety equipment.

• relieve any pressure in the system.

• consult plant MSDS files for hazardous material regulations.

5.2 Disassemble equipment in accordance with equipment

manufacturer’s instructions to allow access to seal installation
area.

5.3 Remove existing mechanical seal and gland or compression

packing and packing gland.

5.4

!

Make sure the shaft or sleeve and the seal housing face are

clean and free of burrs, cuts, dents, or corrosion that might cause
leakage past the sleeve packing



or gland gasket

G

. Replace

worn shaft or sleeve. Remove sharp edges from keyways and
threads.