www.herrmidifier-hvac.com

Communications Fault

A short has been detected in the RS-485

communications loop.

Maintenance is required.

Green power lamp and LCD are not illu-

minated.

Blown 24 VAC control fuse

Short in control wiring or microprocessor

board if fuse blows immediately.
Short in contactor or control wiring if fuses

blow as unit energizes contactor.
Short in fill valve or wiring if fuses blow

after unit is attempting to energize the fill

valve.
Short in drain valve or wiring if fuses blow

after unit has cycled and is now attempt-

ing to energize the drain valve.

Blown high voltage fuses

Spike in power supply.
Short in terminal blocks or contactor

Main transformer failure

Check for 24 VAC on secondary side of

transformer between X1 and X2.
If secondary side is insufficient and proper

voltage is being supplied to primary side

of transformer, replace transformer.

Incorrect voltage to primary side of trans-

former

Confirm voltage supplied compared to tap

on transformer and data plate.

Measure AC voltage across the primary

of the transformer for supplied voltage

If insufficient, check path through terminal

blocks, contactor and fuses for a potential

drain.

If every point of connection within the

humidifier reads the same insufficient

number, then the disconnect should be

checked.

Unable to turn unit on after pressing “on/

off” button

Open door and press “on/off” button again.

If unit comes on, place 1 and 2 wires to the

opposite side of the door interlock switch.
Poles 1 & 3 on the controls terminal strip

need to be jumped.

Water always draining when drain sole-

noid is closed

Obstruction keeping the drain solenoid

from closing

Clean and/or replace.

Display shows erroneous number and

titles (such as “%*#~?/*@”)

Press reset button on the back of the PC

board
Check for proper ribbon cable connec-

tions to LCD and PC board (see page 22,

Item E)
Replace ribbon connector, LCD and PC

board.